An air conditioner's wattage comes from two numbers on its label: its cooling capacity in Btu per hour and its efficiency rating (EER or CEER). Divide the first by the second: watts = Btu/h ÷ EER. A 5,000 Btu window unit rated 11 uses about 455 watts; a 36,000 Btu (3-ton) central AC rated 11 about 3,270 watts while the compressor runs.
AC wattage and cost calculator
Air conditioner power
Month = 30 days. Running watts are for the compressor and fans at rated conditions; on very hot days AC units draw somewhat more. Startup takes a brief surge, important when sizing a generator.
AC unit wattage chart
Running watts at an EER of 11 and of 13, with cost per hour at the U.S. average of 18.16 cents per kWh:
| AC size | Watts at EER 11 | Watts at EER 13 | Cost/hour at EER 11 |
|---|---|---|---|
| 5,000 Btu window | 455 | 385 | 8.3¢ |
| 8,000 Btu window | 727 | 615 | 13.2¢ |
| 10,000 Btu window | 909 | 769 | 16.5¢ |
| 12,000 Btu (1 ton) | 1,091 | 923 | 19.8¢ |
| 24,000 Btu (2 ton) | 2,182 | 1,846 | 39.6¢ |
| 36,000 Btu (3 ton) | 3,273 | 2,769 | 59.4¢ |
| 48,000 Btu (4 ton) | 4,364 | 3,692 | 79.2¢ |
| 60,000 Btu (5 ton) | 5,455 | 4,615 | 99.1¢ |
Watts = Btu/h ÷ EER. One ton of cooling = 12,000 Btu/h. Real units vary; use your label.
EER, CEER, and SEER2 explained
- EER (energy efficiency ratio) = Btu/h of cooling ÷ watts used, measured at a hot test condition. It's the right number for converting Btu to watts.
- CEER (combined EER) is the rating on room and window air conditioners; it also counts standby power. Use it the same way.
- SEER2 is the seasonal rating for central air and heat pumps, averaged over a range of temperatures. It's higher than EER for the same unit, so dividing Btu/h by SEER2 underestimates peak watts but is reasonable for estimating season-long use.
A higher rating means fewer watts for the same cooling. Going from EER 11 to 13 cuts power by about 15%, the gap between the two columns above.
Do window AC units use a lot of electricity?
Not compared with central air. A 5,000 Btu unit at about 455 watts running 8 hours a day uses 3.6 kWh, about 66 cents a day at the average price, or under $20 a month. Window units only cool one room, though, and a home with several running can approach the cost of central AC. Portable air conditioners usually use more power for the same cooling than window units, because their hose and the hot air they pull from the house reduce their efficiency.
Central air conditioner wattage and yearly use
A typical 3-ton central air conditioner draws roughly 3,000 to 3,600 watts while the compressor runs, on a 240-volt circuit. In EIA's household survey, homes with air conditioning used an average of 2,318 kWh a year for cooling, plus another 457 kWh for the air handler fan in homes that have one, about $420 a year for the AC alone at 18.16 cents. Hot, humid states use several times that. Air conditioning is the largest single use of electricity in U.S. homes, about 22% of the total nationally. For the full picture, see the electricity usage calculator.
Lowering AC costs
- Set the thermostat a few degrees higher when you're home and higher still when you're away; every hour the compressor doesn't run saves its full wattage.
- Replace or clean filters regularly and keep the outdoor unit clear of leaves and plants.
- Close blinds on sunny windows and use ceiling fans to feel cooler at a higher setting.
- When replacing, compare EER and SEER2 ratings; a heat pump also replaces the furnace for heating. See heat pump cost.
Common questions
How many watts does a 5,000 BTU air conditioner use?
About 455 W at a CEER of 11 (5,000 ÷ 11).
How many watts does a central air conditioner use?
About 1,000–1,200 W per ton while running for typical units; a 3-ton system draws roughly 3,000–3,600 W.
Do window AC units use a lot of electricity?
A 5,000 Btu unit for 8 hours uses about 3.6 kWh, around 66¢ a day at the average price.
How many amps does an air conditioner use?
Watts ÷ volts: about 3.8 A for a 455 W window unit at 120 V; about 13.6 A for a 3,270 W central unit at 240 V while running.
Sources
- U.S. Energy Information Administration, Residential Energy Consumption Survey 2020, Tables CE5.1a and CE5.3a (air conditioning 2,318 kWh and air handlers for cooling 457 kWh per household using; share of household electricity).
- EIA, Electric Power Monthly, Table 5.6.A, August 2026 (price).
- Rating definitions: U.S. Department of Energy test procedures for room and central air conditioners (EER, CEER, SEER2).