To find what size generator you need, add up the running watts of everything you'll power at once, then add the extra starting watts of the biggest motor. Tick what you want to run below. The wattages are typical ratings you can change; for the most accurate answer, copy the watts from each appliance's label.
Generator wattage calculator
| Run | Appliance | Running W | Starting W | Qty |
|---|
Recommended size = running total + 20% margin, rounded up to the next 500 W, and never below the peak. Starting watts for motors use the DOE rule of thumb that motors draw about 3× their running current at startup; heaters, lights, and electronics have no extra surge. 240 V appliances need a generator with a 240 V outlet or a transfer switch.
How to size a generator in four steps
- List what must run at the same time. In an outage, that's usually the refrigerator, freezer, furnace fan or a window AC, a sump or well pump, some lights, phone chargers, the internet router, and a TV.
- Find each one's running watts. The label lists watts, or amps you can multiply by 120 (or 240 for large appliances). The appliance wattage chart has Department of Energy ranges.
- Add the largest starting surge. Motors need a burst of extra power for a second or two to start. Since motors rarely start at the exact same moment, you only add the extra surge of the biggest one.
- Add a margin. Generators run better and longer below their maximum rating; aim for your running total to be no more than about 80% of the generator's running watts.
Example: refrigerator (210 W running, 630 W starting), furnace fan (750 W), deep well pump (1,100 W), 10 LED bulbs (100 W), TV and router (125 W), and a microwave (1,100 W). Running total: 3,385 W. The well pump's extra starting watts (2,200 W) bring the peak to 5,585 W. A generator with about 6,000 running watts (and starting watts above 5,585) covers it with margin; that is the result the calculator gives with its default selections.
Running watts vs starting watts
Generators list two numbers. Running (rated) watts are what the generator can supply continuously. Starting (surge or peak) watts are what it can deliver for a few seconds when a motor starts. The Department of Energy notes that a motor draws about three times its running current at startup, which is why a refrigerator that runs at about 200 watts can briefly need around 600.
- High surge: refrigerators and freezers, air conditioners, well and sump pumps, furnace blowers, washing machines, power tools with motors.
- No surge: space heaters, water heaters, toasters, coffee makers, incandescent lights, and most electronics draw the same at start as while running.
Central air conditioners have a very large startup surge. A soft-start kit, installed by an HVAC technician, lowers it so a smaller generator can start the compressor.
What different generator sizes can run
| Generator (running watts) | Typical use |
|---|---|
| 2,000–3,500 W (inverter or small portable) | Refrigerator, lights, phones, TV, router, a fan; camping and RVs |
| 4,000–5,500 W | Essentials plus a sump or well pump, or a window AC, or the furnace blower |
| 6,500–9,500 W | Essentials plus several bigger loads; a 240 V well pump; some small central ACs with a soft start |
| 10–26 kW (home standby) | Most or all of a house, depending on central AC, electric heat, range, and dryer |
For a closer look at what each portable size runs, including 3,500, 5,000, and 10,000-watt models, see what a generator can run. For standby costs, see whole house generator cost.
Sizing a generator for a whole house
Whole-house sizing depends on which large electric loads you have, not on square footage. A house with gas heat, gas water heating, and a gas range needs far less than an all-electric house of the same size. The biggest drivers are central air conditioning, electric resistance heat or heat pump backup strips, an electric water heater, range, and dryer, plus a well pump. A load calculation by the installer, sometimes with a load-management module that sheds big appliances when the generator is near its limit, sets the final size.
Generator safety
- Never run a generator indoors, in a garage, or near open windows. Exhaust carbon monoxide can kill within minutes. Keep it at least 20 feet from the house with the exhaust pointed away, and use battery-powered CO alarms inside.
- Don't plug a generator into a wall outlet ("backfeeding"). It can electrocute utility workers and neighbors. Connect to home circuits only through a transfer switch or interlock installed by an electrician.
- Use heavy-duty cords rated for the load, and don't overload them.
Common questions
What size generator do I need?
Running watts of everything at once, plus the largest motor's extra starting watts, plus a margin. Essentials often fit 3,000–5,000 W; central AC needs much more.
What are starting watts?
The short surge a motor needs to start, about 3× its running current per DOE. Generators list a higher starting rating to cover it.
What size generator do I need to run a house?
5,000–7,500 W portable with a transfer switch for essentials; 10–26 kW standby for most or all of a house.
Can a generator run central air?
Yes, if it covers the compressor's starting surge; a soft-start kit lowers the surge so a smaller unit works.
Sources
- U.S. Department of Energy, Energy Savers, typical appliance wattages and motor starting current guidance (as reproduced in Virginia Cooperative Extension BSE-301).