A BTU (British thermal unit) is the amount of heat that raises one pound of water by 1°F. Heaters, air conditioners, furnaces, and fuels are all rated in BTU or Btu per hour. This page has two calculators: one sizes an air conditioner for a room, and one converts watts and fuels to BTU, including the heat output of electric heaters.
Room BTU calculator (cooling)
Based on ENERGY STAR's room air conditioner sizing chart and its adjustments for sun, people, and kitchens.
How many BTU for this room?
ENERGY STAR room air conditioner sizing chart
| Area to be cooled (sq ft) | Capacity needed (Btu/h) |
|---|---|
| 100 to 150 | 5,000 |
| 150 to 250 | 6,000 |
| 250 to 300 | 7,000 |
| 300 to 350 | 8,000 |
| 350 to 400 | 9,000 |
| 400 to 450 | 10,000 |
| 450 to 550 | 12,000 |
| 550 to 700 | 14,000 |
| 700 to 1,000 | 18,000 |
| 1,000 to 1,200 | 21,000 |
| 1,200 to 1,400 | 23,000 |
| 1,400 to 1,500 | 24,000 |
| 1,500 to 2,000 | 30,000 |
| 2,000 to 2,500 | 34,000 |
Source: ENERGY STAR, room air conditioner sizing guidance. An oversized AC cools quickly but shuts off before removing humidity, leaving the room clammy; an undersized one runs constantly.
BTU conversion calculator
Convert to BTU
Heat content: EIA "Energy Explained" Btu conversion factors (propane 91,452 Btu/gal; heating oil 137,381 Btu/gal; natural gas about 1,036 Btu/cu ft, which varies slightly by year and supply; 1 therm = 100,000 Btu; 1 kWh = 3,412 Btu).
Heater BTU: electric, gas, and propane
Electric heaters: multiply watts by 3.412. A 1,500-watt heater gives 5,118 Btu/h, a 750-watt setting 2,559 Btu/h, and a 5,000-watt garage heater 17,060 Btu/h. All electric resistance heat converts 100% of its electricity to heat in the room. See space heater cost to run.
Furnaces: gas and propane furnaces are usually listed by input Btu/h. The heat delivered to your home is input × AFUE (annual fuel utilization efficiency). A 40,000 Btu/h furnace at 95% AFUE delivers about 38,000 Btu/h; at 80% AFUE, about 32,000. A 100,000 Btu/h, 96% unit delivers about 96,000.
Gas stoves: cooktop burners are rated by input, commonly from a few thousand Btu/h for a simmer burner to well over 10,000 for a power burner; check the range's spec sheet.
Fuel use: a 40,000 Btu/h propane heater running flat out burns 40,000 ÷ 91,452 = about 0.44 gallons an hour. A furnace with 60,000 Btu/h input running 8 hours a day uses 480,000 Btu, 4.8 therms of natural gas.
Estimating BTU for heating a home
Heating load depends on climate, insulation, windows, air leaks, and ceiling height, so square footage alone gives only a rough idea. The professional method is an ACCA Manual J load calculation, which HVAC contractors should run before sizing a furnace or heat pump; an oversized system short-cycles and wears faster. If you're replacing equipment, last winter's fuel use is a useful check: divide the gas or propane used in the coldest month by the hours in that month, convert to Btu/h with the factors above, and compare with the old unit's output to see whether it was much bigger than needed. Costs for new equipment are on furnace replacement cost and heat pump cost.
Common questions
How many BTUs is a 1,500-watt heater?
About 5,118 Btu/h (1,500 × 3.412).
How many BTUs are in a gallon of propane?
About 91,452 (EIA). Heating oil about 137,381; natural gas about 1,036 per cubic foot.
How many BTUs do I need to cool a room?
5,000 for 100–150 sq ft up to 12,000 for 450–550 sq ft (ENERGY STAR), with adjustments for sun, people, and kitchens.
What does a 40,000 BTU furnace mean?
Usually 40,000 Btu/h input. At 95% AFUE it delivers about 38,000 Btu/h.
How many watts is 10,000 BTU?
10,000 ÷ 3.412 = 2,931 watts of heat. An AC with that capacity uses far fewer electrical watts (about 909 at EER 11).
Sources
- ENERGY STAR, room air conditioner sizing chart and adjustments.
- U.S. Energy Information Administration, Energy Explained: units and calculators (Btu content of fuels).
- Air Conditioning Contractors of America (ACCA), Manual J residential load calculation.